Broadcom Limited MegaRAID Firmware Release 

**********************************************


**************************************************************************************************************************
***********PLEASE READ IF USING CACHEVAULT OPTION ON ANY OF THESE MEGARAID CONTROLLERS ***********************************
**************************************************************************************************************************
Due to changes required to support new features in this release, after upgrading to any MR 7.3 (50.3.x-xxxx) or later 
package, downgrading to MR 7.2 or MR 7.1 (50.2.x-xxx or 50.1.x-xxxx) is not allowed.
**************************************************************************************************************************
**************************************************************************************************************************


Release date: 09/25/17

====================== 
Supported Controller:
======================

MegaRAID SAS 9460-16i 


Component:
=========
SAS MegaRAID Firmware Release for MegaRAID Controllers
Release date: 09/25/17


Version Numbers:	
===============
Current Package Details:
Firmware Package: 50.3.0-0707 (MR 7.3)
Firmware  5.030.00-0945
ROMENV 1.12
BootBlock 7.02.00.00-0017
NVDATA  5.0300.01-0036
UEFI_Driver  0x07030400 (Signed)
Hii 07.03.11.00 (SIGNED)
FCODE 4.17.08.00
BIOS 07.03.02.0
SBR: 5.0300.01-0286

Previous Package Details:
Firmware Package: 50.2.1-0589 (MR 7.2)
Firmware  5.020.00-0838
ROMENV 1.12
BootBlock 7.02.00.00-0015
NVDATA  7.02.00.00-0016
UEFI_Driver  0x07020400 (Signed)
Hii 07.02.05.00 (SIGNED)
FCODE 4.17.08.00
BIOS 07.02.03.0
SBR: 268


Bug Fixes and Enhancements:
===========================
Firmware:
SCGCQ01404432 - Update nvram.h with correct size for curAdpPersonality
SCGCQ01439507 - JBOD IO's stopped on both MR/iMR Controller, after upgrading/downgrading from MR 7.3 PKG 657 to MR 7.1
SCGCQ01415120 - Raid Map and Pd sync are updated for every OCR
SCGCQ01408312 - Reduce number of block-pairs used for 8GB offload
SCGCQ01415608 - MR7.3_Regression_Controller time is not picked up during bootup
SCGCQ01418180 - NVDATA: Change Default SGPIO electrical driving strength from 50 to 66 Ohm 
SCGCQ01421427 - Data abort exception during OCR with JBODs
SCGCQ01424266 - Revert SCGCQ01418180 for 3616 and 3508 XSD, 3408 and 3416 remains the same.
SCGCQ01425554 - Integrate MR PL-SCS Libs: SASFW_Ventura_Phase_5.0 04.250.09.00
SCGCQ01388735 - Store the RAID SubDevID in NVRAM to have a reference to original RAID-ID - NVRAM changes
SCGCQ01373260 - [NVRAM] Warning removal 1295
SCGCQ01421154 - Prevent Improper Flash from ISSI Supported SBR/FW to non-ISSI Supported SBR/FW when Board has ISSI Chip
SCGCQ01413785 - Parameter Page Reads fail during ONFI bringup.
SCGCQ01412186 - pdRef filled incorrectly in bvd->Physical_Disk_Sequence[] causing DDF to skip added PD in Recon
SCGCQ01421154 - Prevent Improper Flash from ISSI Supported SBR/FW to non-ISSI Supported SBR/FW when Board has ISSI Chip
SCGCQ01411024 - Flash write Failed with err code 5
SCGCQ01411329 - Shutdown command received from host" missed in tty log

Boot Block:
SCGCQ01357917 - Boot Block Accesses PCI_LINK_CONFIG while PCE Core is Reset

NVDATA:
Miscellaneous changes for various products

UEFI_Driver:
SCGCQ01407043 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01345378 - MR7 PNP additions
SCGCQ01351616 - Change the logic for reentering to main entry point in UEFI Driver
SCGCQ01384314 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01321203 - Reset Type and customer messaging for system resets initiated by controller OpROM
SCGCQ01321228 - When user unloads UEFI Driver nullify pHiiHandShakeProtocol and ask platform to free HII (memory and image handle)
SCGCQ01301650 - Cursor below text and in center of line on the system reset request screen.
SCGCQ01309119 - Debug print shown on the console from the UEFI Driver error path.
SCGCQ01349428 - Firmware Management Protocol - Firmware update fails with inappropriate message when trying to update an unsigned
component

Hii:
SCGCQ01330410 - Add Requeted Profile ID field in Profile Management form.
SCGCQ01397706 - Check All option is not working properly in Make JBOD form
SCGCQ01407043 - If waitForKey is False suppress "Enter Your Input Here:" string
SCGCQ01388767 - HII is showing internal backplane drives in triplet format instead of duplet.
SCGCQ01401629 - Secure Virtual Disk checkbox not selected by default when Security is Enabled on the controller
SCGCQ01343778 - Question ID assignment for item under suppressif TRUE and the same item that gets created at runtime
SCGCQ01344008 - HEFU: Delay seen during boot in case of 240 PD configuration.
SCGCQ01344658 - Customize the configuration help message.
SCGCQ01355025 - Silence Alarm: Use tech pub suggested help string
SCGCQ01379764 - HII Advanced VD properties shows "CacheCade Type" primitive
SCGCQ01376325 - An empty page is seen when reconstruction is triggered.
SCGCQ01372698 - LockKeyFailed is set with junk value from Controller info
SCGCQ01387373 - "The requested command has invalid arguments" message is seen after importing 150+ virtual drives.
SCGCQ01388677 - Connector Name is truncated in the "Disk Name string" in Disk Management
SCGCQ01396828 - Unable to convert all UG drives to JBOD while 2 enclosure connected
SCGCQ01406386 - Internal Backplane is showing as an enclosure in HII Dashboard View
SCGCQ01352041 - RSOD seen when user browse to Enclosure Management Page
SCGCQ01354659 - HII Create Virtual Disk option is selectable even before choosing drives for the VD
SCGCQ01412729 - HII - Select Span option shown after creating a VD with no Unconfigured drives remaining
SCGCQ01348156 - Foreign Configuration Preview screen also has entries of virtual drives that are optimal in state.
SCGCQ01337568 - HII: Enumeration of drives
SCGCQ01335254 - Prompt string should be unique
SCGCQ01345617 - Remove unsupported features from the HII Main Menu Help tab
SCGCQ01359020 - Add new card support in HII
SCGCQ01325348 - With secured foreign SED, it is asking you to enter the Passphrase/password.
SCGCQ01291052 - User must be warned when they create a VD across the front backplane and enclosures behind the switch
SCGCQ01376269 - Internal bpis showing up as an encl which causes HII to show the enumeration incorrectly - implement new MR API
SCGCQ01345378 - MR7 PNP additions
SCGCQ01350528 - Select RAID level using QID under suppressif TRUE and then same primtiive generated at runtime
SCGCQ01321222 - HEFU: Sort the connector names, when the names are not in Port 0 -3 format
SCGCQ01344341 - Incorrect Drive Group numbering in "Create Virtual Drive" menu
SCGCQ01351616 - Change the logic for reentering to main entry point in UEFI Driver
SCGCQ01385162 - For SuperCap, HII has the primitive 'Remaining Capacity' which is different compared to other host utilites
SCGCQ01400115 - The physical drive operation % increase in progress is not getting updated
SCGCQ01321208 - When user unloads UEFI Driver nullify pHiiHandShakeProtocol and ask platform to free HII (memory and image handle)
SCGCQ01333899 - Inappropriate message shown when the Reconstruction is initiated again while the previous reconstruction is in progress.
SCGCQ01384314 - With pinned cache generated, HII is auto launched during system Boot when BIOS Mode is set to Ignore Errors.
SCGCQ01321189 - Foreign configuration page seen after changing profile to NVMe.
SCGCQ01321203 - Reset Type and customer messaging for system resets initiated by controller OpROM
SCGCQ01389129 - In the 'Manage SAS Storage Link Speed' form, not able to move the cursor to the next entry.
SCGCQ01407030 - Check All is not working in Assign Dedicated HotSpare form
SCGCQ01334156 - HEFU: Don't check the return value for the function to get connector index and sorted connnector index
SCGCQ01321185 - HII shows wrong Temperature value when Sensor status is "Not Installed"
SCGCQ01334144 - Not able to select check box in some forms
SCGCQ01386798 - Not able to disable JBOD mode when there is file system/operating system present on the controller configuration.
SCGCQ01321210 - HEFU - Sort the disk based on connector name, slot and position
SCGCQ01301650 - Cursor below text and in center of line on the system reset request screen.
SCGCQ01309119 - Debug print shown on the console from the UEFI Driver error path.
SCGCQ01348104 - Click on "OK" button after completing any operation doesn't have any effect in the screen
SCGCQ01349428 - Firmware Management Protocol - Firmware update fails with inappropriate message when trying to update an unsigned
component

BIOS:
SCGCQ01292708 - Drive ID shown in BIOS POST is more than 1000+, even thought the total drives is only about 160
SCGCQ01379327 - System reset is initiated twice in BIOS
SCGCQ01321554 - Reset Type and customer messaging for system resets initiated by controller optrom


Installation:
=============
Use StorCLI to flash the SAS controllers.  These tools can be downloaded from the support and download
section of www.broadcom.com.

Command syntax:  
StorCLI /c0 download file=9460-16i_nopad.rom


=================================
=================================
Previous Releases
=================================
=================================

Component:
=========
SAS MegaRAID Firmware Release for MegaRAID Controllers
Release date: 07/11/17


Version Numbers:	
===============
Current Package Details:
Firmware Package: 50.2.1-0589 (MR 7.2)
Firmware  5.020.00-0838
ROMENV 1.12
BootBlock 7.02.00.00-0015
NVDATA  7.02.00.00-0016
UEFI_Driver  0x07020400 (Signed)
Hii 07.02.05.00 (SIGNED)
FCODE 4.17.08.00
BIOS 07.02.03.0
SBR: 268

Previous Package Details:
Firmware Package: 50.1.0-0501 (MR 7.1)
Firmware  45.010.00-0671
ROMENV 1.12
BootBlock 7.02.00.00-0015
NVDATA  4.1610.00-0136
UEFI_Driver  0x07010700 (Signed)
Hii 07.01.12.00 (SIGNED)
FCODE 4.17.08.00
BIOS 07.01.05.0
SBR: 260


Bug Fixes and Enhancements:
===========================
Firmware:
SCGCQ01229409 - (Closed) - Remove workaround put in SCGCQ01215385 and handle profile change.
SCGCQ01242091 - (Closed) - Redundant path broken for PD 00(e0x40/s0) message for OS Disk when removing a known bad SATA SSD from a different slot.
SCGCQ01249966 - (Closed) - Inconsistencies in foreign configuration import when cache is pinned.
SCGCQ01264038 - (Closed) - Storcclif start diag DMA Test failed
SCGCQ01264210 - (Closed) - After performing Clear/PD erase on SATA SSDs system hangs (PL Fault)
SCGCQ01265753 - (Closed) - SbrMemInit() is not implemented correctly and needs to be fixed
SCGCQ01268736 - (Closed) - MR 7.2 NVMe : MonTask: line 331 in file ../../raid/taskman.c rst=0 when trigger OCR
SCGCQ01270379 - (Closed) - 9440-8i iMR, Overtemp LED always on. This is due to incorrect NVDATA setting on "Active" low vs Active High
SCGCQ01272468 - (Closed) - Fatal firmware error: Line 934 in ../../cpu/arm/exceptions.c while Enclosure power cycle
SCGCQ01273488 - (Closed) - Few Virtual Disk Tasks Missing, Once After Deleting One of The Multiple Partial Virtual Disk
SCGCQ01274092 - (Closed) - Physical and Logical sector size not showing correctly with a 512e PD.
SCGCQ01274813 - (Closed) - Enclosure not supported; too many enclosures connected to port message when connecting a 2nd enclosure in Multipath.
SCGCQ01278343 - (Closed) - Checkin NVRAM debug variable
SCGCQ01278826 - (Closed) - Disable RMC EEPROM Ring buffer dump for Mercury controllers.
SCGCQ01279555 - (Closed) - ACT LED is staying on - FW fix for Activity LED blink on iMR
SCGCQ01279806 - (Closed) - Guest OS encountered error/no controller found while attempting to install windows driver
SCGCQ01282458 - (Closed) - controller Driver version showingInformation Not Available even drivers installed
SCGCQ01282538 - (Closed) - Data Abort Exception Error seen and RAID reconstruction fails on Adapter during reboots
SCGCQ01282624 - (Closed) - 9440-8i - system hung during Hibernate test in JBOD mode under Win10
SCGCQ01284586 - (Closed) - Storcclif start diag DMA loop test hit Montask
SCGCQ01284977 - (Closed) - Consolidating CSETs from 7.0.1 stream to 7.1 stream
SCGCQ01286579 - (Closed) - MR 7.0.1: iMR FW hangs after rebuild is started on a hotspare drive that's been reclaimed
SCGCQ01287610 - (Closed) - Controller breaks into Megamon when BGI/CC hits uncorrectable errors.
SCGCQ01288526 - (Closed) - MR 7.1 9440-8i operating at only half the frequency
SCGCQ01289603 - (Closed) - enclosure redundant path show as not present and extra entry of enclosure is seen
SCGCQ01290856 - (Closed) - Command error when unlocking SATA SSD (ATA Security Unlock)
SCGCQ01291098 - (Closed) - MR firmware hanging while waiting for BIOS restart after COL with power glitch
SCGCQ01292507 - (Resolved) - Storclif returns failure with Description "Corrupted Image" when user tries to flash any other package
SCGCQ01295086 - (Closed) - With the fixes provided for OLTP issue, other regressions were observed.
SCGCQ01295102 - (Closed) - FW Hung and System Halted, after clicking on 'Manage PCIe Storage Interface' option of HII
SCGCQ01296135 - (Closed) - OS sluggishness observed during non-OS VD RLM (R0 to R1).
SCGCQ01297312 - (Closed) - Issue found during devBST
SCGCQ01300625 - (Closed) - Code was indexing outside of array boundaries when the number of bits were not evenly divisible by the storage entry size. This is a form of an "off by one" error
SCGCQ01300834 - (Closed) - FW hangs during init upon subsequent boots of a VMWare VM with a passthrough enabled controller
SCGCQ01301947 - (Closed) - In HII whether entering the correct pass phrase or the wrong pass phrase a secured SED becomes unsecured
SCGCQ01302574 - (Closed) - Profile issue: pkg 411 either set to profile 10 or profile 11 after reboot see " Profile Id 1 is optimised"
SCGCQ01304715 - (Closed) - Firmware hit PL Fault 0000d033 when pull out multiple drives
SCGCQ01305741 - (Closed) - HW: DMA hang
SCGCQ01306312 - (Closed) - FW is not returning the mfistat MFI_STAT_OK_REBOOT_REQUIRED for profile change
SCGCQ01307460 - (Closed) - Issue- Code review found ldQDepth was not properly set after a merge.
SCGCQ01312210 - (Closed) - MR7.2_NVMe: FW Crash obseved, after making the VD offline which is going under RLM operations and querying about the CTRL
SCGCQ01312338 - (Closed) - MR-7.2: iMR 9440-8i:Hit PL Fault 0000d073 LinkRegister f407e703 During I/O With CablePull
SCGCQ01312356 - (Closed) - FW hits ../../cpu/arm/exceptions.c when deleting multiple degraded and offline VDs
SCGCQ01313079 - (Closed) - MR7.2: Cannot set PI enabled drive as JBOD
SCGCQ01313152 - (Closed) - Removing an assert on immediate prp IO path
SCGCQ01313223 - (Closed) - Fix for DC on couple of R0/R6 VD's, after running IO's using Chaos IO tool in presence of Medium Error
SCGCQ01314319 - (Closed) - Data corruption on R6 WB VD when there are medium errors on one PD
SCGCQ01315127 - (Closed) - Error occur when performing Diagnostic on controller ( error 57 )
SCGCQ01316489 - (Closed) - MR7.2 While IO and cable pull /push on second enclosure hit :Assertion failure in ../../dm/mpt2/mptframe.c at line 788
SCGCQ01316557 - (Closed) - Firmware hit exception when running IO on NVMe drives
SCGCQ01320514 - (Closed) - Ventura MR - Controller faults when phy disable commands are issued (ARM Exception)
SCGCQ01320680 - (Closed) - The message "Failed chip" was occuring when accessing phys that don't exist or beyond an array range.
SCGCQ01324233 - (Closed) - Minimize amount of time spent in FIQ processing
SCGCQ01326057 - (Closed) - FW Profile Get API needs to return correct pending Profile ID
SCGCQ01328726 - (Closed) - Hit MonTask: line 1597 in file ../../raid/inc/raid.h rst=0 When Pullout two drives on R6 With I/O
SCGCQ01329147 - (Closed) - Used to check in changes for SCGCQ01315685 Raid Level Migration Slow issue.
SCGCQ01341346 - (Closed) - system hung during stress test in JBOD mode under Win10
SCGCQ01342194 - (Closed) - Ventura MR - Linux 64 JBOD SAS HDDs 4K SW 64QD controller crashes
SCGCQ01344153 - (Closed) - MR_7.2_NVMe:Fatal firmware error: Line 939 in cpu/arm/exceptions.c found while pull out drives when copy back in progress
SCGCQ01344718 - (Closed) - Change gNvramInterCoreRequestRmwNvramBuffer to a pointer for dynamic memory allocation
SCGCQ01349554 - (Closed) - Messages "LD unsync'd" messages spewing during specific cornercase of offline/pincached LDs
SCGCQ01349963 - (Closed) - IOs to LD stops while upgrading/downgrading between MR7.1/MR7.2
SCGCQ01350465 - (Closed) - always showed initialization 0% in UEFI Setup after expand or re
SCGCQ01351273 - (Closed) - MR 7.2 : Multiple drives remove mising remove events cause StorCLI/FW still see drives eventhough drives already got remove
SCGCQ01351850 - (Closed) - Fix code collab AIs
SCGCQ01352146 - (Closed) - Implement the CRC check to try the old method if the new method fails.
SCGCQ01353249 - (Closed) - Add "UseNewVendorIdOnOcr" to nvram.h
SCGCQ01353693 - (Closed) - Fixing MCTP FIQ interrupt policies
SCGCQ01357859 - (Closed) - Firmware should block to downgrade MR 7.2 NVMe profile to MR 7.1 SAS/SATA profile
SCGCQ01364118 - (Closed) - No rebuild LED on  server ( work with previous ROP 536)
SCGCQ01252549 - (Closed) - SW R10 HDD WB 8K 256QD 30% regressions
SCGCQ01259740 - (Closed) - MR-7.0.1: iMR 9440-8i - Hit KillAdapter during SATA Rebuild With double ME injection on R50 of mixed SATA/SAS drives
SCGCQ01264584 - (Closed) - Not able to perform CLEAR operation on SED drives
SCGCQ01265460 - (Closed) - 7.2[UNMAP] If LD is marked unmap capable,HSP commissioned for this LD needs to checked for unmap capabilities
SCGCQ01274084 - (Closed) - FW is not correctly reporting Hide VD operation as not supported
SCGCQ01277951 - (Closed) - RAID10 VD goes to failed state after performing RLM
SCGCQ01278680 - (Closed) - reporting "Complete with Errors" after failing to create all requested 63 Virtual Disk creation
SCGCQ01281338 - (Closed) - MR7.2_NVMe: FW Kill Adapter observed, after degrading R6 Dual Core Capable VD's
SCGCQ01282517 - (Closed) - Added code to calculate buffer pointer for each lba in case original MPTframe has PRPs.
SCGCQ01285181 - (Postponed) - Consolidating CSETs from OEM stream to 7.1 stream
SCGCQ01288722 - (Closed) - FW faults with dma Error during boot time cache flush
SCGCQ01288767 - (Closed) - Misc fixes for UNMAP feature in recovery path
SCGCQ01288908 - (Closed) - to re check in changes in SCGCQ01264210
SCGCQ01288912 - (Closed) - Code cleanup
SCGCQ01288968 - (Closed) - Use nvmesge to hold 2nd prp and in case more than 2 prps is required for an IO, copy the 2nd sge from nvmesge to first 8 bytes of prpbuffer.
SCGCQ01290566 - (Closed) - Assertion failure in ../../dm/inc/mptDirect.h at line 127 found while running task resets on JBODS
SCGCQ01293954 - (Closed) - Backing out change for SCGCQ01278947, as this change fail devBST with KA 
SCGCQ01299784 - (Closed) - irq handler flooding taskqueue and persistent ID removal corrupting memory
SCGCQ01300886 - (Closed) - multi-path test failed. Enclosure lost
SCGCQ01302348 - (Closed) - Write Uncorrectable Flag is shown as 0 for same drives.
SCGCQ01306755 - (Closed) - To check validity of LD before requesting pinned cache related checks in foreign import scenario
SCGCQ01306895 - (Closed) - MR 7.2 : Can not boot back to OS after update to ROP 415
SCGCQ01306918 - (Closed) - MR7.2_NVMe: FW Kill Adapter observed, after degrading R6 Dual Core Capable VD'
SCGCQ01308353 - (Closed) - Locate LED is not blink for all PD
SCGCQ01310524 - (Closed) - MR 7.2 : A lot of DmRecoverIoError(retr 1) display in firmware log when system idle
SCGCQ01311303 - (Closed) - Update PL version check for PL version assert
SCGCQ01330761 - (Closed) - Event Log API does not account for instances when LD ID may be set to LD_INVALID
SCGCQ01331391 - (Closed) - Patrol Read event string looks corrupted (PD id and elapsed time are not proper)
SCGCQ01331911 - (Closed) - Process all failed lmid in PL_MptDirectIoFailedList for the device that is getting removed before final devIoWait Queue clean up.
SCGCQ01336908 - (Closed) - Rebuild Rate %100 takes much longer time than %30 while running IO. It should take much shorter time.
SCGCQ01349171 - (Closed) - MR-7.2: iMR 9440-8i:Hit PL Fault 0000620b LinkRegister f40dc68f During I/O With CablePull
SCGCQ01349231 - (Closed) - MR-7.2: iMR 9440-8i: Not Detecting Any NVME Drives After Updating Fw 684 to FW 709
SCGCQ01349236 - (Closed) - SES DCDB does not complete, causing Kill Adapter
SCGCQ01355038 - (Closed) - iMR 9440-8i:Hit MonTask: line 279 in file ../../dm/src/devDisc.c rst=0 During CablePull
SCGCQ01270724 - (Closed) - CC finds inconsistent parity after correcting reference tag errors.
SCGCQ01272668 - (Closed) - Live FW log and tty/termlog don't match
SCGCQ01273950 - (Closed) - Assertion failure in ../../dm/src/FindDev.c at line 282 (DmDISMCleanup) while mutipath push/pull of enclosure
SCGCQ01281364 - (Closed) - In case Firstsge->count is less than Length of the IO, the length of the sub-IO is equal to Firstsge->count (not the calculated residualBytes).
SCGCQ01283385 - (Closed) - ECC correctable errors seen on some boards
SCGCQ01287927 - (Closed) - Not able to update NVMe PD firmware in imr
SCGCQ01287930 - (Closed) - [PL DFCT]MR 7.2 NVMe :Firmware hit dm.c when pull/insert drive
SCGCQ01289128 - (Closed) - on starting reconstruction with IO will result in montask
SCGCQ01289615 - (Closed) - Added supported profile bitmap string to firmware environment data
SCGCQ01304713 - (Closed) - FW hit Kill Adapter while running Drive Pull BST test case
SCGCQ01306919 - (Closed) - Dev Defect to add BCA implementation enable code.
SCGCQ01307027 - (Closed) - 7.2 AI move #defines to SCSI instead of Pd.h
SCGCQ01310502 - (Closed) - Data abort exception seen with SATA devices discovery
SCGCQ01310634 - (Closed) - Child defect: LMID Q FULL error <Parent SCGCQ01215294>
SCGCQ01313185 - (Closed) - I/O drop when trigger OCR
SCGCQ01330774 - (Closed) - PD becomes unconfigured bad after clearing the configuration.
SCGCQ01338825 - (Closed) - Hit Kill Adapter Montask When Pull out All The Drives
SCGCQ01345699 - (Closed) - PL Faults with code 0000e40a.
SCGCQ01375574 - (Closed) - Initiate Ocr after FW raises assert
SCGCQ01265814 - (Closed) - controller fails to POST after FW update to pkg 334 (SCGCQ01264849)
SCGCQ01274220 - (Closed) - Learn cycle doesn't complete after I2C disrupted during disharge step of LC
SCGCQ01278947 - (Closed) - curQDepth not decremented on failed exit of mptdirect:: MptDirectStartIo().
SCGCQ01283702 - (Resolved) - SCS/PL debug logs for "rb", "tb", or "dmdiag pl dbg" are sometimes mangled due to multiple mprintf's overlapping
SCGCQ01284753 - (Closed) - Series of OCR seen during media recovery; System hangs during boot after AC cycle
SCGCQ01285002 - (Closed) - Issue found in dev BST
SCGCQ01288897 - (Closed) - Resulting R0 VD is showing as not consistent after reconstruction.
SCGCQ01289627 - (Closed) - Tm active flags not cleared for msg completions
SCGCQ01304521 - (Closed) - Firmware crashes during medium error recovery and Rebuild
SCGCQ01310542 - (Closed) - OEM branded iMR 9440-8i card randomly blinks Error/Fault LEDs on disk backplane during VD Full initialization
SCGCQ01338852 - (Closed) - Hit Data Miscompare after single Cache offload
SCGCQ01338876 - (Closed) - RMC and CPLD out of Sync in COL cases
SCGCQ01338907 - (Closed) - Revert CSET SCGCQ01318920
SCGCQ01346339 - (Closed) - Remove DRAID sources
SCGCQ01229224 - (Closed) - OS sluggishness observed during non-OS VD RLM (R0 to R1).
SCGCQ01274053 - (Closed) - FW Kill Adapter observed, while running IO's on R10 VD's along with CC in background
SCGCQ01279498 - (Closed) - creating file system parallely on 16 raid 0 vd's which support unmap will result in montask
SCGCQ01297381 - (Closed) - defect not to report UNMAP sizes in VPD pages, if VD is not UNMAP capable
SCGCQ01309937 - (Closed) - FW Upgrade/Downgrade[From PKG 414 to 419] Failed with storlib Error Code 8017
SCGCQ01315130 - (Closed) - Controller faults with SATA HDDs when expanders are reset (Assertion Failure)
SCGCQ01316581 - (Closed) - Code is attempting to validate DMA'able address in SGL when writing backup for recon operation.
SCGCQ01292705 - (Closed) - Fatal firmware error: Line 934 in ../../cpu/arm/exceptions.c during RHEL 7.3 insatllation with JBOD
SCGCQ01305638 - (Closed) - Child Defect for WG: After clearing config while VD erase is in progress, new VD created still continues to show "STOP ERASE"
SCGCQ01373217 - (Closed) - We now print the SPI Library version and we can print out SPI Library debug when there is an issue
SCGCQ01330296 - (Closed) - MR 7.2 NVMe : iMR Reconstruction is very slow
SCGCQ01263777 - (Implemented) - Extended Trace Buffer implemented for both MR and iMR
SCGCQ01315212 - (Closed) - Integrated PL Phase 3 version 03.25.00.00 into 7.2 FW
SCGCQ01320690 - (Closed) - PD Latency framework
SCGCQ01323199 - (Closed) - PL Library Integration 03.25.01
SCGCQ01341622 - (Closed) - Add new flag in Nvram to support single imaee cache offload.
SCGCQ01328837 - (Closed) - Integrated PL Library_Phase 3.0 Version 03.25.02.00 into 7.2 FC Int Stream.
SCGCQ01358028 - (Closed) - PL Library Integration Phase_3.0 - 03.25.04.00
SCGCQ01300603 - (Implemented) - Firmware flash support thru IMM, while HII is running.
SCGCQ01304043 - (Closed) - Removing UNMAP code from the 7.2 stream
SCGCQ01306882 - (Implemented) - This is the NVRAM.h piece of the implementation.
SCGCQ01300720 - (Closed) - Enhancement to restrict Unmap feature to R0
SCGCQ01252330 - (Port_Complete) - Set Newest seqnum to clear seqnum via Factory Defaults
SCGCQ01256760 - (Port_Complete) - TTYlog generated Debug Alarm message
SCGCQ01261531 - (Port_Complete) - iMR cable pull: IO Drop on VDs
SCGCQ01261533 - (Port_Complete) - Host I/O reached PD during PD FW Download causing PD enter fail state (both host I/Os and PD FW Download fails too)
SCGCQ01265784 - (Port_Not_Required) - RSOD been observed after disabling Data protection on PI enabled VD
SCGCQ01269365 - (Port_Complete) - Critical Message = " Error restoring offload cache " during IO running to R50 with power loss
SCGCQ01276571 - (Port_Complete) - Patrol read resume event not captured through storcli after host reboot
SCGCQ01276573 - (Port_Complete) - Newly computed values not saved in NVRAM in a particular case
SCGCQ01276574 - (Port_Complete) - Foreign drives can be set for prepare for removal
SCGCQ01278934 - (Port_Complete) - Implement code to notify BIOS driver of a faultless restart
SCGCQ01281491 - (Port_Complete) - SBR reload is not working when update to new ROP which have new SBR and do warm reboot
SCGCQ01283484 - (Port_Complete) - Assertion failure in ../../raid/cache.c during repeated power cycle test runs
SCGCQ01283717 - (Port_Complete) - 24 SAS SSD 32K RW QD 4+ 14% regression
SCGCQ01284955 - (Port_Complete) - RAID10 VD goes to failed state after performing RLM
SCGCQ01287694 - (Port_Complete) - Fix CcrSetDrCtrl
SCGCQ01291689 - (Port_Complete) - Improvements for offload/restore reliability
SCGCQ01291749 - (Port_Complete) - cmd ID released while cmd blk member is still in use
SCGCQ01291781 - (Port_Complete) - MR 7.0.1: iMR FW hangs after rebuild is started on a hotspare drive that's been reclaimed
SCGCQ01293513 - (Port_Complete) - Hang at DDR training while running COL glitch test
SCGCQ01294955 - (Port_Complete) - FW keeps hitting "Assertion failure in ../raid/mficmd.c at line 831: c->status!=FREE_COMMAND" while looping foreign import
SCGCQ01295774 - (Port_Complete) - Disable controller BIOS, Controller in fault state (caused by reset during COL glitch test) Windows driver not loaded
SCGCQ01305476 - (Port_Complete) - MR-7.0.1: iMR 9440-8i - Hit KillAdapter during SATA Rebuild With double ME injection on R50 of mixed SATA/SAS drives
SCGCQ01307024 - (Port_Complete) - FW:Add capability to expose each SAS Expander-attached SEP as a separate Enclosure PD
SCGCQ01311311 - (Port_Complete) - BST 7.3 (8GB) ==> Flash firmware and reboot post message showed "the maximum allowable limit of 3 enclosures"
SCGCQ01317671 - (Port_Complete) - MR 7.2_Beta_NVMe LED is staying on
SCGCQ01319763 - (Port_Complete) - [PL]While BGI running, reboot the system with 240LDs created, caused FW hitting DataAbortException montsk()
SCGCQ01319826 - (Port_Complete) - ECC Error spike observed during Cache Restore when read eye training failed.
SCGCQ01322092 - (Port_Complete) - MR7.1: Unexpected event for lun not ready Sense: 2/04/02
SCGCQ01322095 - (Port_Complete) - Cache Data lost if power loss happens during descriptor preparation.
SCGCQ01322149 - (Port_Complete) - RDM in Use-RDm Error & crashed into Montask during boot
SCGCQ01325219 - (Port_Not_Required) - HW: DMA hang
SCGCQ01330085 - (Port_Complete) - Implemented handling for firmware upgrade/downgrade incompatible firmware and profile
SCGCQ01331394 - (Port_Complete) - iMR-7.1: With a 32 single-drive R0 VDs config, added UGood drives become Foreign UBad drives
SCGCQ01331435 - (Port_Complete) - FW is not reporting Underrun status for RW Ios in the legacy JBOD IO path
SCGCQ01331534 - (Port_Complete) - FW entered Exception mon_task while importing foreign PDs in loop.
SCGCQ01332374 - (Port_Complete) - PKG 465\ When a Migration starts fw eventually breaks
SCGCQ01333107 - (Port_Complete) - Security Key provided for importing Foreign Config is not taken by LSA 02.79
SCGCQ01336063 - (Port_Complete) - MonTask:...fusion.c rst=0 with Driver detected possible FW hang
SCGCQ01339616 - (Port_Complete) - Hang When Updating Chipset Drivers in Windows
SCGCQ01343449 - (Port_Complete) - Raid level migration failing on MR
SCGCQ01343894 - (Port_Complete) - Enclosure ID for the new PD inserted on system comes as 0xff
SCGCQ01344506 - (Port_Complete) - StorCLI Reports Incorrect Flash Size for controller with -0360 FW
SCGCQ01344510 - (Port_Complete) - Controller disappears from F1 Setup (HII) After Removing Secured JBOD from System and Rebooting
SCGCQ01344716 - (Port_Complete) - 7.3 pk484 unxpctd c_ptr 19804640 tgtId ef while migrate from 2DR1 -> 4DR6
SCGCQ01345807 - (Port_Complete) - Enumerate GPIOs based on CCR
SCGCQ01346496 - (Port_Complete) - PA1: fw hit PL D10D while format partition
SCGCQ01349904 - (Port_Complete) - Persistent mapping is employed regardless of the directPdMapping setting.
SCGCQ01352518 - (Port_Complete) - MR_7.3_FW : MonTask: line 332 in file ../../raid/taskman.c rst=0 while trying to delete 128 R0 DGs
SCGCQ01352742 - (Port_Complete) - If an INVALID applicationMsgTag id received, then failed the command with MFI_OOB_STATUS_INVALID_CMD using command id MAX_OOB_COMMANDS.
SCGCQ01353553 - (Port_Complete) - Insert a BAD SSD into active controller will cause FW Hung
SCGCQ01356872 - (Port_Complete) - Controller restart command hung during IO on VD's and Jbod's
SCGCQ01370416 - (Port_Complete) - LSA hangs when user try to change drive security key.
SCGCQ01266184 - (Port_Complete) - 'C0:mr_wakeup: mem 45569e20, cache line ffffffff' observed while running BGI on RAID 5 Volume with media errors.
SCGCQ01270523 - (Port_Complete) - Controller MonTask while running BGI corrected medium error
SCGCQ01279292 - (Port_Complete) - SBR reload is not working when update to new ROP which have new SBR and do warm reboot
SCGCQ01283516 - (Port_Complete) - IOMeter Random Write performance reduced by ~32% when OS is installed to controller.
SCGCQ01293512 - (Port_Complete) - server hangs at BIOS banner following power cycle in COL test
SCGCQ01322225 - (Port_Complete) - Drive is not marked as Foreign upon OCR when controller already has max configured PD's
SCGCQ01323454 - (Port_Complete) - Firmware returns only firmware supported profile id data for Host Appl Get Profile command
SCGCQ01325253 - (Port_Complete) - If the profile type is not supported on a downloaded image, the image will not get flashed.
SCGCQ01325299 - (Port_Complete) - Dynamic interrupt priority change for MCTP during FW download
SCGCQ01325397 - (Port_Complete) - SEP PD ID is not consistent
SCGCQ01326836 - (Port_Complete) - FW hangs if you try to update the FW using stroelibtest in IMM debug while trying to navigate in HII controller menu.
SCGCQ01326927 - (Port_Complete) - Controller hang with FDE Drive 
SCGCQ01329170 - (Port_Complete) - Remove HDD from backplane always remain green light 
SCGCQ01330206 - (Port_Complete) - montask while running AC cycle test during the 'cache offload testing'. Controller break into montask with Error Data Abort exception.
SCGCQ01331477 - (Port_Complete) - Data loss during cache offload power cycle test
SCGCQ01336972 - (Port_Complete) - showed initialization 0% in UEFI Setup after expand or re
SCGCQ01337578 - (Port_Complete) - controller fails to complete an OCR
SCGCQ01338902 - (Port_Complete) - FW enters an infinite loop of Exception Frame dumps if an exception is hit early boot
SCGCQ01341643 - (Port_Complete) - fw hit cache.c when pull out NVMe pd in r0 to generated pinned cached.
SCGCQ01344364 - (Port_Complete) - MR7.1 : MemsetECache prints fill important termlog space
SCGCQ01344514 - (Port_Complete) - Handling stuck MCTP transactions in hardware queues after ignore VDM bit is set
SCGCQ01344715 - (Port_Complete) - 7.3: NVMes Only pk 462 Fatal firmware error: Line 934 in ../../cpu/arm/exceptions.c when migrate 2DR1->4DR6
SCGCQ01347514 - (Port_Complete) - controller wil not boot up after downloading the corrupted images ( app.rom, SBR, BTBL .. etc) because of CRC mismatch.
SCGCQ01351185 - (Port_Complete) -  no MCTP response after several OOB FW update without system reboot - Firmware Flash issue
SCGCQ01352522 - (Port_Not_Required) - Dev Defect: Don't refer LMID before dism start in the case of device hot plug
SCGCQ01357915 - (Port_Complete) - displays invalid characters or blank for connector name
SCGCQ01302176 - (Port_Complete) - SAS2208 card reset in DataCenter due to unknown reason
SCGCQ01322091 - (Port_Complete) - MR_6.11_FW: Data corruption seen on IMR controller on JBOD with raw IO using smash tool- sles OS
SCGCQ01325244 - (Port_Not_Required) - If the profile type is not supported on a downloaded image, the image will not get flashed.
SCGCQ01325443 - (Port_Complete) - 14G:SWPT: Enclosure hotremoved and insert it back,one physical disk is missing in storage inventory.
SCGCQ01329786 - (Port_Complete) - After a system reboot during BGI FW reports Consistency Check started instead of Background Initialization resumed
SCGCQ01332528 - (Port_Complete) - Expander FW update fails with "The expander firmware update failed while downloading the firmware to controller" error
SCGCQ01339607 - (Port_Complete) - montask after data abort exception handler was called
SCGCQ01342228 - (Port_Complete) - MR7.3: while multiple rebuilding on 240LDs, FW prints constantly messages "C0:Rebuild delayforHeadOfQ..............."
SCGCQ01342432 - (Port_Complete) - Storecli "show autopdcache" command blocks for 2min40sec during IO.
SCGCQ01342767 - (Port_Complete) - Crusader: fw Assertion failure in ../../raid/ld.c at when insert pd
SCGCQ01342882 - (Port_Complete) - MR7.3 -[EVT#Disabling writes to flash due to a critical error.] Reported in FW Debug logs during test.
SCGCQ01346994 - (Port_Complete) - IOMMU fault at address 0x80360000
SCGCQ01349265 - (Port_Complete) - MR firmware hanging while waiting for BIOS restart after COL with power glitch
SCGCQ01358352 - (Port_Complete) - Set the appropriate ( DM_IO_CTX_FLAG_INT_CFG_REQ ) flag to indicate that mptfarme/mid is allocated for internal config
request so that frame will be released inside DmPlConfigPage after the allocation purpose is served.
SCGCQ01374556 - (Port_Complete) - CPU Error Occurs During DC Cycle with 530-8i (Boynton)
SCGCQ01387820 - (Active) - Initiate ocr when FW enters MonTask
SCGCQ01283716 - (Port_Complete) - MR 7.1 NVMe BST : One PD lost after reboot server
SCGCQ01284695 - (Port_Complete) - Hang at DDR training while running COL glitch test
SCGCQ01290779 - (Port_Complete) - IMR_6.10 : OFU fails in Windows IMR/MR 6.6 -> greater than MR/iMR 6.6 -> MR/iMR 6.6 due to Language Attrib
SCGCQ01330328 - (Port_Complete) - MR-7.1: FW exception when power off/power one last cascaded drives enclosure on SLES 12 SP1 x64
SCGCQ01333025 - (Port_Complete) - JBOD drop during cable pull test.
SCGCQ01333842 - (Port_Complete) - MR 7.1_Double Dip COL causes loss of disk cache
SCGCQ01335211 - (Port_Complete) - To close the window during which ONFI is not armed even when the data is dirty
SCGCQ01333109 - (Port_Complete) - Avoid the deadlock while removing the PD during bootup insertion process
SCGCQ01342418 - (Port_Complete) - Handle underrun cases for STP reply for DISM
SCGCQ01346493 - (Port_Complete) - Mode page access to same devId needs to be serialized
SCGCQ01350074 - (Port_Complete) - Data exception and FW crash at line 934 in ../../cpu/arm/exceptions.c
SCGCQ01353447 - (Port_Complete) - Drives reported as missing after pinned cache flush is interrupted at SOD
SCGCQ01358139 - (Port_Complete) - Assertion failure in ../../hw/inc/3516_inc/memory.h at line 405: isInAddressibleRange(physAddrLow)
SCGCQ01387366 - (Port_Complete) - 9400 IT Channel product firmware detecting memory read error during bootup
SCGCQ01343638 - (Port_Complete) - Insertion of Faulty drive results in FW failure.

Boot Block:
SCGCQ01320842 - (Closed) - Montask in Pbam.c during COL A/C cycle testing
SCGCQ01324235 - (Closed) - Increase padding

NVDATA:
Miscellaneous changes for various customers
SCGCQ01276636 - (Closed) - Storcli shows wrong output for the command storcli /c0 show profile
SCGCQ01284278 - (Closed) - NVData changes to sync with PL Phase 3.0
SCGCQ01287743 - (Closed) - Phase 3.0 PL NVDATA is not backwards compatible with phase2.0 NVDATA.
SCGCQ01294880 - (Closed) - OEM SAS/SATA Incorrect LED behaviors on Purely system
SCGCQ01307015 - (Closed) - Update 7.2 NVData with PL Phase 3.0
SCGCQ01310403 - (Closed) - OEM branded iMR 9440-8i card randomly blinks Error/Fault LEDs on Intel disk backplane during VD Full initialization
SCGCQ01311305 - (Resolved) - Product name for 28i reported 9460-28i. Should be 9365-28i.
SCGCQ01312331 - (Resolved) - Misc changes and cleanup requested for OEM
SCGCQ01315220 - (Closed) - Fix the connector info for OEM
SCGCQ01315949 - (Closed) - Clean up connector info in MrMfgPage0 and ManPage7
SCGCQ01317486 - (Resolved) - [NVData] MR 7.2_Beta_NVMe  LED is staying on
SCGCQ01349791 - (Closed) - MR9460-28i reported in dmesg. Should be MR9365-28i
SCGCQ01358573 - (Closed) - crashed with MR 7.2 package 541
SCGCQ01365306 - (Closed) - Update OEM XML files up to sync with 7.3 CQ NVDATA content.
SCGCQ01283683 - (Closed) - OEM 9440-8i/9460-16i product name not showing up correctly
SCGCQ01316749 - (Resolved) - Hit Assertion failure in ../../raid/profile.c at line 1063 After Update ROP 428 To 429
SCGCQ01317867 - (Resolved) - Increase the drive strength of GlobalActivity GPIO on 8i cards to 66Ohms
SCGCQ01374772 - (Closed) - 7.2 Nvdata Disable external port for Nvme on  9480-8i8e 
SCGCQ01290879 - (Resolved) - Phase 2.0 PL-MR NVData Sync for OEM Backplane detection
SCGCQ01358590 - (Closed) - OEM Workstation_NVMe drives show & & & in the drive management
SCGCQ01368441 - (Closed) - OEM's 9460-8i - NVMe SSD Drives fail to be Detected by Controller FW
SCGCQ01378093 - (Closed) - Junk characters are shown in HII PD menu on 24i controller.
SCGCQ01342309 - (Closed) - Update NVDATA from default values for EDFB in page 30
SCGCQ01352028 - (Closed) - MR 7.2 : Set EnableJBOD=0 by default for 28i controller
SCGCQ01307656 - (Closed) - Update NVData Broadcom 94xx series MR and iMR Cards to correct Drive Strength setting for Internal Conn. Sidebands (GPIOs)
SCGCQ01385103 - (Resolved) - MR PARAMS page 0 does not get updated with the newer ROP that has NVDATA with a change in the same page.
SCGCQ01347812 - (Closed) - MR 7.2 : Assertion ../../cfg/cfgisup.c at line 1306: (ptrMfg6->NumGPIO) after update to ROP 520+ OFU with Darlington board
SCGCQ01300466 - (Resolved) - Update Connector names to C0,C1,C2,C3 for all channel cards
SCGCQ01322347 - (Closed) - Fix disableCacheBypass in OEM
SCGCQ01284685 - (Closed) - added support for two new OEM boards for 7.1 Program
SCGCQ01291022 - (Closed) - Enabling NVMe drive detection for 9460-8i controller behind OEM backplane.
SCGCQ01299181 - (Closed) - MR_SAS_NVDATA3.5_CORE sync changes to MR_SAS_NVDATA3.5_7.1_FC_Int
SCGCQ01300992 - (Closed) - Add PnP ID for their 3516 ROMB design
SCGCQ01318994 - (Closed) - Sync up 3516.xsd and 3508.xsd MrParamPage0 extra field for 7.2 NVDATA CORE with 6.11 NVDATA
SCGCQ01295313 - (Closed) - Enable SSC options Additional NVDATA changes for Custom OEM NVDATA Request (ProductRequest:SCGCQ01263316)
SCGCQ01309260 - (Closed) - Custom OEM WS NVDATA Request
SCGCQ01314618 - (Closed) - Add Updated 3716 Board NVDATA
SCGCQ01282524 - (Closed) - Slot Mapping NVDATA changes for OEM 9460-8i
SCGCQ01294973 - (Closed) - 7.2 FC Nvdata Integration with PL Phase 3 Nvdata Integration.
SCGCQ01378946 - (Implemented) - Request to Update Drive Spin-Up Settings on Controllers
SCGCQ01297306 - (Implemented) - updated NVDATA settings as required for 7.1 RC
SCGCQ01381125 - (Implemented) - Enabling amber LED activity on SAS/SATA drives.

UEFI_Driver:
SCGCQ00883008 - (Closed) - Profile Mgmt API Changes
SCGCQ00886417 - (Closed) - MR_RAID_CTX_G35 has one too many bits
SCGCQ00927738 - (Closed) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO
SCGCQ00948535 - (Closed) - The code had events with repetitive ID and some structures clashing
SCGCQ01001936 - (Closed) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23
SCGCQ01014835 - (Closed) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Ventura Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4
SCGCQ01272576 - (Closed) - UEFI Driver: Driver Health message is missing during critical boot message handling
SCGCQ01305604 - (Closed) - Remove Print (or replace with OutputString) in GET PD Info error path from UEFI Driver
SCGCQ01264142 - (Closed) - New fault code for routine synchronous reset
SCGCQ01114969 - (Closed) - MR 7.2: Add API support to make application work with Cachecade3.0 (Public)
SCGCQ01222700 - (Closed) - API changes for PCIe lane/link speed
SCGCQ01222698 - (Closed) - API change for Simplified RAID10 Creation
SCGCQ01218406 - (Closed) - API Changes Required for Specific OEM Backplane functionality
SCGCQ01215334 - (Closed) - API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli
SCGCQ01203751 - (Closed) - API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue
SCGCQ01146597 - (Closed) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY
SCGCQ01141251 - (Closed) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES
SCGCQ01139344 - (Closed) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters
SCGCQ01137627 - (Closed) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C
SCGCQ00867953 - (Closed) - profile management API
SCGCQ00875328 - (Closed) - Mega API modifications needed for RMW-FP and Cache bypass features
SCGCQ00883262 - (Closed) - Merging api_overrides mega_api files with the files in the Mega_API development stream
SCGCQ00941620 - (Closed) - de-feature AHCI
SCGCQ01023741 - (Closed) - MR_CTRL_INFO expansion from 2K to 4K
SCGCQ01059740 - (Closed) - mega api changes for ibuttonless PR
SCGCQ01075821 - (Closed) - Profile Management Changes to support requestedProfileID and optimisedProfile
SCGCQ01094549 - (Closed) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO
SCGCQ01133839 - (Closed) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file
SCGCQ01188725 - (Closed) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register
SCGCQ01213092 - (Closed) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile
SCGCQ01185306 - (Closed) - UEFI Driver: ARM Support for SAS/SATA (BST level)
SCGCQ01351452 - (Port_Complete) - Change the logic for reentering to main entry point in UEFI Driver
SCGCQ01321199 - (Port_Complete) - UEFI_Driver: Remove VID/DID for EVAL (AA) from Supported
SCGCQ01275420 - (Port_Complete) - UEFI Driver: Driver Health message is missing during critical boot message handling
SCGCQ01260950 - (Port_Complete) - Dual controller hangs at random during POST while "Initializing Firmware Interfaces" followed by an RSOD!
SCGCQ01301649 - (Port_Complete) - Cursor below text and in center of line on the system reset request screen.
SCGCQ01277943 - (Port_Complete) - Issues in UEFI driver when FW is in fault state
SCGCQ01261626 - (Port_Complete) - Issues in UEFI driver when FW is in fault state
SCGCQ01261640 - (Port_Complete) - Return EFI_UNSUPPORTED if UEFI Driver already manages one controller.
SCGCQ01260947 - (Port_Complete) - Saving Changes dialogue box appears after handling UEFI critical message
SCGCQ01321230 - (Port_Complete) - When user unloads UEFI Driver nullify pHiiHandShakeProtocol and ask platform to free HII (memory and image handle)
SCGCQ01276819 - (Port_Complete) - MR 7.0.1.1: UEFI Driver: Support new fault code 0xfe
SCGCQ01277937 - (Port_Complete) - Remove VID/DID of SAS3, SAS2.5, SAS2 from Supported
SCGCQ01242795 - (Port_Complete) - Driver health shows as Failed even after handling the boot message.
SCGCQ01235507 - (Port_Complete) - OS installation on JBOD (windows or Linux) not working
SCGCQ01242793 - (Port_Complete) - Driver health shows as Failed even after handling the boot message.
SCGCQ01295418 - (Port_Complete) - UEFI Driver: Reset Type and customer messaging for system resets initiated by controller optrom
SCGCQ01277940 - (Port_Complete) - Return EFI_UNSUPPORTED if UEFI Driver already manages one controller.
SCGCQ01261638 - (Port_Complete) - Remove VID/DID of SAS3, SAS2.5, SAS2 from Supported
SCGCQ01349429 - (Port_Complete) - FMP Firmware update Fails with proper Firmware after trying to update an unsigned firmware
SCGCQ01278453 - (Port_Complete) - Saving Changes dialogue box appears after handling UEFI critical message
SCGCQ01277933 - (Port_Complete) - Controller hangs at random during POST while "Initializing Firmware Interfaces" followed by an RSOD!
SCGCQ01276572 - (Port_Complete) - MR 7.0.1.1: UEFI Driver: Support new fault code 0xfe
SCGCQ01339882 - (Port_Complete) - UEFI Driver: Reset Type and customer messaging for system resets initiated by controller optrom

Hii:
SCGCQ00844774 - (Closed) - Handle coverity defects
SCGCQ00883008 - (Closed) - Profile Mgmt API Changes
SCGCQ00886417 - (Closed) - MR_RAID_CTX_G35 has one too many bits
SCGCQ00927738 - (Closed) - Reintroduce numSGEExt Field in Raid Context for Invader to support 1MB IO
SCGCQ00948535 - (Closed) - The code had events with repetitive ID and some structures clashing
SCGCQ01001936 - (Closed) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Dev API baseline dated 2015-12-23
SCGCQ01014835 - (Closed) - CtrlInfo.adapterOperations3.supportProfileChange is missing in Dev API baseline dated 2015-12-23 has been added back again into adapteroperations 4
SCGCQ01317576 - (Closed) - Foreign configuration seen after changing profile to NVMe
SCGCQ01320795 - (Closed) - MR 7.2.1: help text is missing for available controller profiles in HII Progile Management menu
SCGCQ00825741 - (Closed) - UEFI Driver: Compilation error when debug Flags are enabled
SCGCQ01001944 - (Closed) - FW 5045 returns MFI_STAT_DEVICE_NOT_FOUND for read capacity (0x9E)
SCGCQ01040687 - (Closed) - Typecast target ID to U16 while calling MakeLdRdWrFrame
SCGCQ01282545 - (Closed) - View Enclosure Status: HII shows wrong Temperature when Sensor staus is not installed
SCGCQ01203810 - (Closed) - handle coverity defects
SCGCQ01282179 - (Closed) - HII:handle coverity defects
SCGCQ01264142 - (Closed) - New fault code for routine synchronous reset
SCGCQ00813457 - (Closed) - UEFI Driver: Rebranding effort for System X - MR 6.6 PnP Additions for OEM
SCGCQ01222700 - (Closed) - API changes for CR55 - PCIe lane/link speed
SCGCQ01222698 - (Closed) - API change for Simplified RAID10 Creation
SCGCQ01218406 - (Closed) - API Changes Required for Specific OEM Backplane functionality
SCGCQ01215334 - (Closed) - API changes for PR SCGCQ01139678 - Method for determining bad ONFI flash in storcli
SCGCQ01203751 - (Closed) - API changes for PR SCGCQ01127742 - Isolating faulty cable issue from bad drive issue
SCGCQ01146597 - (Closed) - MR 6.12 - Add JBOD mode personality to MR_CTRL_PERSONALITY
SCGCQ01141251 - (Closed) - MR 7.0: Add supportPdMapTargetId flag in MR_CTRL_INFO and MFI_CAPABILITIES
SCGCQ01139344 - (Closed) - MR 6.13: Add API support for TFM/SCAP _MR_BBU_VPD_INFO_FIXED parameters
SCGCQ01137627 - (Closed) - MR 6.13: Add a new control command to fetch ROC temperature data over I2C
SCGCQ01114969 - (Closed) - MR 7.2: Add API support to make application work with Cachecade3.0  (Public)
SCGCQ00867953 - (Closed) - profile management API
SCGCQ00875328 - (Closed) - Mega API modifications needed for RMW-FP and Cache bypass features
SCGCQ00883262 - (Closed) - Merging api_overrides mega_api files with the files in the Mega_API development stream
SCGCQ00941620 - (Closed) - de-feature AHCI
SCGCQ01023741 - (Closed) - MR_CTRL_INFO expansion from 2K to 4K
SCGCQ01059740 - (Closed) - mega api changes for ibuttonless PR
SCGCQ01075821 - (Closed) - Profile Management Changes to support requestedProfileID and optimisedProfile
SCGCQ01094549 - (Closed) - MEGA_API Changes to incorporate new IO subtype to support redirect cached IO
SCGCQ01133839 - (Closed) - MR 7.0: Add MR_RAID_FLAGS_IO_SUB_TYPE_LDIO_BW_LIMIT = 7 to mfi.h file
SCGCQ01188725 - (Closed) - Define CurrentFwNvmePageSize element in new MFI_REG_STATE_EXT3 register
SCGCQ01213092 - (Closed) - MR7.1. Add MR API bit to indicate the profile is NVMe Only profile
SCGCQ01172039 - (Implemented) - 7.1: Add Eval board DID
SCGCQ00890699 - (Closed) - UDK2014 : Port UEFI Driver to UDK2014
SCGCQ00939634 - (Closed) - UEFI BSD: Add support for controllers
SCGCQ01040653 - (Implemented) - Add support for new DIDs
SCGCQ00834720 - (Closed) - PNPs and support for 16 port 12G designs
SCGCQ00927365 - (Closed) - port UEFI BSD for ARM64
SCGCQ01088729 - (Implemented) - Boot message handling when preboot utility is not present or disabled
SCGCQ01185306 - (Closed) - UEFI Driver: ARM Support for SAS/SATA (BST level)
SCGCQ01088779 - (Implemented) - Add support for 3716 0xD0 and 3616 0xD1
SCGCQ00934986 - (Closed) - UEFI BSD: 512 PD/VD support
SCGCQ01172034 - (Closed) - UEFI Driver: Adhere to MR API related to mrConfigExt2Supported and ctrlInfoExtSupported
SCGCQ00939596 - (Port_Not_Required) - OS doesn't boot after installing OS on the 100th VD , while having 240 VDs created in EFI mode
SCGCQ01271787 - (Port_Complete) - MR 7.0.1.1 HEFU: Add HiiVersion to the Formset Title only for MERCURY DEBUG builds
SCGCQ01272169 - (Port_Complete) - Check Hw present alarm field before displaying Alarm fields
SCGCQ01272188 - (Port_Complete) - HII not providing error message when selecting an invalid number of PDs for a R10 VD.
SCGCQ01272210 - (Port_Complete) - HII does not allow user to change the expansion percentage when performing a capacity expansion
SCGCQ01275420 - (Port_Complete) - UEFI Driver: Driver Health message is missing during critical boot message handling
SCGCQ01349387 - (Port_Complete) - Clicking "OK" button after completing any operation doesn't have any effect in the screen
SCGCQ01372727 - (Port_Complete) - LockKeyFailed is set with junk value from Controller info
SCGCQ00989358 - (Port_Complete) - Driver health protocol: Remove default value from Numeric primitive and add OEM proprietary Varstore GUID
SCGCQ01235167 - (Port_Complete) - Fix sorting and SupportMorethan16Phys issue
SCGCQ01251182 - (Port_Complete) - Dashboard view, Disk Group inconsistency. R10 with 42 PD showing DG=3.
SCGCQ01271650 - (Port_Complete) - Clean up Save TTY log function as it has stale code
SCGCQ01271782 - (Port_Complete) - CSCvc89473(CSC.nuova,N-A,paddpadm)PL: TTY log with file size 2kb specified downloaded from HII shows 4kb size
SCGCQ01272176 - (Port_Complete) - DKM are still listing up in change security mode polices as well as in help page Menu observed
SCGCQ01272263 - (Port_Complete) - ASSERT text seen on screen when entering system menu
SCGCQ01272277 - (Port_Complete) - Generic RAID level VD's created with write through & No read ahead policies even for HDD drives.
SCGCQ01276626 - (Port_Complete) - No Dedicated Hotspare option when creating a File Server Profile VD
SCGCQ01277943 - (Port_Complete) - Issues in UEFI driver when FW is in fault state
SCGCQ01279285 - (Port_Complete) - "NULL STRING" seen while creating profile based VD with NVMe drives
SCGCQ01321198 - (Port_Complete) - HII: Remove VID/DID for Eval boards from Supported
SCGCQ01351405 - (Port_Complete) - When you have a secured foreign SED , it is asking you to enter the Passphrase/password.
SCGCQ00950172 - (Port_Complete) - stall() reduction
SCGCQ00950174 - (Port_Complete) - UEFI driver should use text instead of subtitle for boot messages
SCGCQ01271780 - (Port_Complete) - HII show inconsistent status for failed SuperCap
SCGCQ01272184 - (Port_Complete) - Reconfig: Add/Remove PD
SCGCQ01276589 - (Port_Complete) - HII 'View Associated Disk Groups' details under PD mgmt does not display all assigned DHS.
SCGCQ01278456 - (Port_Complete) - HII displays a controller menu for "Syncro"
SCGCQ01279288 - (Port_Complete) - For security key, the length must be upto 32 not 256
SCGCQ01306581 - (Port_Complete) - Compilation warning UDK14 x86/Arm
SCGCQ00950177 - (Port_Complete) - Code refactor: UEFI Driver: Get OEM name in one place
SCGCQ01012459 - (Port_Complete) - Add Support for OEM iMR Board
SCGCQ01171372 - (Port_Complete) - EFI driver test Red-screen-of-death
SCGCQ01272166 - (Port_Complete) - 9460-16i - HDD information show messy code in BIOS when HDDs connected in LSI RAID card
SCGCQ01273166 - (Port_Complete) - HII help file changes
SCGCQ01276592 - (Port_Complete) - HII produces "Success" page for unsuccessful operation when saving controller events
SCGCQ01276606 - (Port_Complete) - Activate Apply Change in Basic VD prop page only when required
SCGCQ01276623 - (Port_Complete) - Save Debug log: Free the memory in error path
SCGCQ01276819 - (Port_Complete) - MR 7.0.1.1: UEFI Driver: Support new fault code 0xfe
SCGCQ01290833 - (Port_Complete) - RSOD observed while entering the PREVIEW FOREIGN Configuration in HII - short-term workaround in HII
SCGCQ01321229 - (Port_Complete) - When user unloads UEFI Driver nullify pHiiHandShakeProtocol and ask platform to free HII (memory and image handle)
SCGCQ00993910 - (Port_Complete) - Need support for reduced feature set in Invader based MegaRAID controller
SCGCQ01016045 - (Port_Complete) - hangs during any device boot: tty shows: C0:GetCacheMemoryFromHost: On 13G servers
SCGCQ01191842 - (Port_Complete) - RSOD encountered on reboot system
SCGCQ01235507 - (Port_Complete) - OS installation on JBOD (windows or Linux) not working
SCGCQ01239440 - (Port_Complete) - SSD erase apps is sending "Standard" as option but firmware fails as "Invalid DCMD"
SCGCQ01239469 - (Port_Complete) - Inconsistency among LSA and Storcli and HII while displaying interface for NVMe drives
SCGCQ01242795 - (Port_Complete) - Driver health shows as Failed even after handling the boot message.
SCGCQ01277937 - (Port_Complete) - Remove VID/DID of SAS3, SAS2.5, SAS2 from Supported
SCGCQ01286461 - (Port_Complete) - MR 7.0.1 No fast/full init after creation of profile based VDs
SCGCQ01321207 - (Port_Complete) - UseSetMem instead of UnicodeSprint (L"")
SCGCQ01333901 - (Port_Complete) - A wrong message displayed in HII reconstruction browser while trying to trigger reconstruction again
SCGCQ01349338 - (Port_Complete) - Customize STR_FORM_HF150_CON_HELPMESSAGE
SCGCQ01273200 - (Port_Complete) - MR7.0.1 HEFU: Remove VID/DID of SAS3, SAS2.5, SAS2 from Supported 
SCGCQ01276586 - (Port_Complete) - Assigned DHS does not show for all DGs in Hii 'View DG properties'.
SCGCQ01277940 - (Port_Complete) - Return EFI_UNSUPPORTED if UEFI Driver already manages one controller.
SCGCQ01279247 - (Port_Complete) - PCI data to be populated for MR cards - short term solution to hard code the values in Hii 
SCGCQ01279260 - (Port_Complete) - Remove all references to Clear PD functionality in HII
SCGCQ01295418 - (Port_Complete) - UEFI Driver: Reset Type and customer messaging for system resets initiated by controller optrom
SCGCQ01337070 - (Port_Complete) - Use SetMem before filling drive name
SCGCQ01351379 - (Port_Complete) - UCM: Prompt string should be unique
SCGCQ01012453 - (Port_Complete) - System BIOS makes user to discard cache before it continues on. cache must be preserved
SCGCQ01264200 - (Port_Complete) - RAID00 shown in list when only one unconfigured drive available for RAID creation
SCGCQ01271785 - (Port_Complete) - Connector name of a NVMe drive is not displayed
SCGCQ01272185 - (Port_Complete) - Help string review change suggested by tech pub for MFI stat error code
SCGCQ01272206 - (Port_Complete) - HEFU MR7.0.1: code review defect: use SetMem() instead of UnicodeSPrint()
SCGCQ01273170 - (Port_Complete) - HII User Interface Changes
SCGCQ01277933 - (Port_Complete) -  hangs at random during POST while "Initializing Firmware Interfaces" followed by an RSOD!
SCGCQ01278453 - (Port_Complete) - Saving Changes dialogue box appears after handling UEFI critical message
SCGCQ01278475 - (Port_Complete) - In HII, Applying Default option temp makes ctrl props values to nil & appears few new attributes in Dashboard view
SCGCQ01351400 - (Port_Complete) - HII: RAID Mode – SAS/SATA/NVMe Mixed Topology Support (64 SAS/SATA, 4 NVMe) (WB)
SCGCQ01241646 - (Port_Complete) - HEFU 7.0.1: fix possible memory leaks
SCGCQ01257920 - (Port_Complete) - HPE: Firmware Flash is not closed properly after the flash.
SCGCQ01271786 - (Port_Complete) - Add WWID for the NVme Drives
SCGCQ01272174 - (Port_Complete) - Remove Physical Disks option should be removed in HII when reconfiguring a R10 VD
SCGCQ01272213 - (Port_Complete) - HII displays 3 supported profiles but only two are support for 7.1 release
SCGCQ01272255 - (Port_Complete) - No information is provided to user while performing cryptographic erase in HII
SCGCQ01292997 - (Port_Complete) - In HII, create-profile-based VD, extra characters show (intermittent)
SCGCQ01344342 - (Port_Complete) - Incorrect Drive Group numbering in "Create Virtual Drive" menu
SCGCQ01349341 - (Port_Complete) - List of VDs displayed in the Foreign Config Preview screen
SCGCQ01351378 - (Port_Complete) - Replace hardcoded SDV Part number with Mass Production (MP) Part Number
SCGCQ01351415 - (Port_Complete) - Select RAID level using QID under suppressif TRUE and then same primtiive generated at runtime

BIOS:
SCGCQ01254368 - (Port_Complete) - MR_6.11_BIOS: POST shows' 252 JBODs handled by BIOS', if case of multiple controllers of same family
SCGCQ01235519 - (Port_Complete) - Legacy OpROM: Handle adding of "boot" string next to SATA system PD at proper offset.
SCGCQ01276576 - (Port_Complete) - Support new fault code 0xfe
SCGCQ01349392 - (Port_Complete) - MR7.3, FW displays the ID in BIOS during boot up more than 1000+, even total drives is only about 160PDs
SCGCQ01254370 - (Port_Complete) - MR_6.11_BIOS: POST shows' 252 JBODs handled by BIOS', if case of multiple controllers of same family
SCGCQ01276821 - (Port_Complete) - Support new fault code 0xfe
SCGCQ01295419 - (Port_Complete) - Reset Type and customer messaging for system resets initiated by controller optrom
SCGCQ01339884 - (Port_Complete) - Reset Type and customer messaging for system resets initiated by controller optrom

SBR:
SCGCQ01341522 - (Closed) - This is to mask unintended powerloss_n NMI from CPLD
SCGCQ01342383 - (Closed) - Add additional debug dumps in timeout events
SCGCQ01343800 - (Closed) - Glitch test failing to restart A15
SCGCQ01349657 - (Closed) - board with ROP504 pkg does not boot show uart on certain motherboards.
SCGCQ01338864 - (Port_Complete) - Set VDD Ramp up Delay to 1 msec



Installation:
=============
Use StorCLI to flash the SAS controllers.  These tools can be downloaded from the support and download
section of www.broadcom.com.

Command syntax:  
StorCLI /c0 download file=9460-16i_nopad.rom






Component:
=========
SAS MegaRAID Firmware Release for MegaRAID Controllers
Release date: 06/16/17


Version Numbers:	
===============
Current Package Details:
Firmware Package: 50.1.0-0501 (MR 7.1)
Firmware  45.010.00-0671
ROMENV 1.12
BootBlock 7.02.00.00-0015
NVDATA  4.1610.00-0136
UEFI_Driver  0x07010700 (Signed)
Hii 07.01.12.00 (SIGNED)
FCODE 4.17.08.00
BIOS 07.01.05.0
SBR: 260


Previous Package Details:
N/A


Bug Fixes and Enhancements:
===========================
**Initial Release**


Installation:
=============
Use StorCLI to flash the SAS controllers.  These tools can be downloaded from the support and download
section of www.broadcom.com.

Command syntax:  
StorCLI /c0 download file=9460-16i_nopad.rom